Ventilation
Why Do Attics Need to be Ventilated?
| Unventilated Attics |
Ventilated Attic |
|
| Summer Temperature | 160 F | 105 F |
| Cooling Costs | 15% Higher |
15% Lower |
| Thermal Expansion of Shingles | Greater | Reduced |
| Moisture Retention in Winter | Elevated | Minimal |
| Living Conditions | Uncomfortable |
Comfortable |
1. Attics that are properly ventilated allow hot air to exhaust from the attic in the summer. The chart above illustrates the advantages of a well-ventilated attic system. Hot air can infiltrate the living space as the attic temperature increases. This makes living conditions uncomfortable and requires the cooling system to work harder. The increased attic temperature also causes greater thermal expansion of the shingles and roof deck. This is a problem that will be discussed in greater detail in regard to the shingle manufacturer’s warranty.
2. Properly ventilated attics allow warm and humid air to exhaust in the winter. The warm air that is trapped in the attic in the winter months can cause several problems, including condensation and ice dams. Condensation occurs when the moist air from inside the house (often from bathroom vents) comes in contact with the cold attic air. Condensation can cause damage to the insulation, wood framing, wood roof deck, and drywall. Ice dams can be eliminated (in some cases) by improving attic ventilation. For details on the causes and effects of ice dams, click here.
3. The life of the roof is extended if the attic is properly ventilated. Most shingle manufacturers require proper ventilation to validate the shingle warranty. It is not uncommon for an unventilated roof system to fail prematurely. Thermal expansion (and contraction) of the shingles and roof deck is the major cause. Higher attic temperatures increase the rate of thermal expansion for the shingles. The shingles that are exposed to higher rates of expansion tend to weaken around the fasteners and the adhesive strips. When the roof deck is exposed to higher temperatures, the resulting thermal expansion can cause the shingles to buckle.
Types of Roof Vents
- Air Intake or Soffit Vents (which unfortunately do not exist on some houses)
- Air Exhaust Vents
Continuous Soffit Vent
Vented Vinyl Soffit
Rectangular Soffit Vent
If Intake or soffit vents have been installed on a house, they can be found on the lower part of the roof system. The four main types of intake vents are continuous soffit vents, rectangular soffit vents, vented vinyl soffit, and specialty intake vents. Continuous soffit vents are the most desirable. A minimum of 50% of the NFVA should be installed as intake vents, if possible. Intake vents should be installed with air baffles which prevent attic insulation from blocking the airflow. It is important to make sure that soffit vents are unobstructed for them to function properly. To do this, look in the attic on a sunny day — if daylight is visible through the vents, they were properly installed.
Ridge Vent
Gable Vent
Roof Louvers or 750 Vent
Power Vent
Exhaust vents are always installed near the ridge or upper part of the roof system. There are many types of roof exhaust vents, including continuous ridge vents, louvers or 750 vents, gable vents, and power vents. The selection of the exhaust vent is a very important consideration that is usually determined by the architectural style of the house. For homes with good intake ventilation, a continuous ridge vent is usually the best choice. The Owens Corning VentSure continuous ridge vent system allows 20 inches of NFVA per foot, making it one of the most efficient ridge vents on the market today.
How the Vents Work
| Exhaust Vents Installed | Intake Vents Installed | Air is Replaced From: | Energy Costs |
| Yes | Yes | Outside Air | Decreased |
| Yes | No | Living Space | Increased |
Designing the Right System
- Calculate the square footage of the attic floor.
- Determine the placement of the intake and exhaust vents.
- Calculate the NFVA for each vent.
- 2000 Sq Ft of attic floor space = 288,000 square inches of attic floor space (2000 x 144)
- 288,000 sq inches/ 300 sq inches = 960 square inches of NFVA required
- Since it is our goal to achieve a balanced system, 960 / 2 = 480 square inches of both intake and exhaust vents should be installed.
Houses without Soffit Area
The architectural style of some houses makes it is very difficult to achieve a balanced ventilation system. Victorian and Cape Cod houses usually have insulation that is blocking the airflow from the soffit area to the exhaust vents. Removing or decreasing the thermal barrier (insulation) in order to achieve better ventilation is not recommended.
Designing the Right System